Inspection |
1. |
There should be continuity between the No.15 and No.7,8 terminals when
power and ground are connected to the No.15 and No.14 in the ICM-A.
|
2. |
There should be continuity between the No.10 and No.12,13 terminals
when power and ground are connected to the No.15 and No.14 in the ICM-A.
|
1. |
There should be continuity between the No.11 and No.12,13 terminals
when power and ground are connected to the No.11 and No.1 in the ICM-A.
|
2. |
There should be continuity between the No.10 and No.7,8 terminals when
power and ground are connected to the No.11 and No.11 in the ICM-A.
|